Safe Torque Off (STO) / Interlock

Servosila SC-120R servo drives come with a "Safe Torque Off / Interlock" port for safety-critical applications.

The STO function disconnects the motor from power at the "bare metal" level. This function makes sure that dangerous machines do not move during maintenance or when not in use, even if firmware, network, an upper layer control system or operators "go crazy".

Whenever the STO pin is low, the STO circuitry physically disconnects the inverter's power switches from the motor. The motor starts coasting. The servo drive itself stays operational.

The same port can be used to "interlock" a master motion control board with its slave servo drives. If the master control board looses power or malfunctions, the voltage on STO pins goes low, the #servo drives are forced to stop.

The STO/Interlock function can be disabled by removing a jumper, when not employed in an application.
  • 🔥 10
  • 👍 2
More from @servosila
  1. Sep 17, 2026ADC Delay Tuning Sweep Servosila SC-120 servo drives come with an ADC Delay Tuning functio…
  2. Sep 10, 2026Starter-Generator: The "Back-Flick" Motion All stock Servosila SC-series Servo Drives can…
  3. Aug 3, 2026Sine Speed Reference Test under Sensorless Field-Oriented Control (FOC) A 10-pole 1550KV e…
  4. Jul 21, 2026Provisioning a sine reference signal or a step reference signal to the input of a servo sy…
  5. Jun 17, 2026A three-axis robotic #gimbal system utilizes Servosila SC-60R servo drives for actuation c…
  6. May 6, 2026Servo Drive support for Dual Encoders Servosila SC-series servo drives provide support for…
Threads Profile ViewerView any public Threads profile without an account.Open ThreadLook →Writing with AI? Make it sound human.Metric37 rewrites AI drafts so they read naturally. Free AI detector, 1,500 words free.Try Metric37 →